meta name="google-site-verification" content="ksSpO4rWauaVhhEAST1fCyJWYhhvF4sYf-UcFEhFmnQ" /> Optex VXI-ST Outdoor Detection PIR | prosafesecurity
top of page

12 m (40 ft.) by 90 degree flexible detection pattern adjustable to 5 ranges
SMDA logic for advanced temperature compensation and environmental noise immunity
Easy masking for over spill prevention
Double conductive shielding against bright light disturbance
Conduit/TX-battery case for both wired and wireless-ready models

862-01-VXI-ST

Optex VXI-ST Outdoor Detection PIR

SKU: AC1128*
R3,010.00Price
  • Model VXI-ST VXI-AM VXI-DAM
    Detection method Passive infrared Passive infrared & Microwave
    Coverage 12.0 m (40 ft) wide / 16 zones
    PIR distance limit 12 - 2.5 m (5 levels)
    Detectable speed 0.3 – 1.5 m/s (1 - 5 ft/s)
    Sensitivity 2.0°C (3.6°F) at 0.6 m/s (2 ft/s)
    Power input 9.5 – 18 VDC
    Current draw 20 mA (max) at 12 VDC 24 mA (max) at 12 VDC 35 mA (max) at 12 VDC
    Alarm period 2.0 ±1 sec.
    Warm-up period Approx. 60 sec. (LED blinks)
    Alarm output N.C. / N.O. Selectable 28 VDC 0.1 A (max)
    Trouble output - N.C., 28 VDC 0.2 A max.
    Tamper output N.C., 28 VDC 0.1 A max.
    LED indicator Red: Warm-up, alarm,masking detection (VXI-AM only) Red: Warm-up, alarm,masking detection.
    Yellow: Warm-up, MW detect.
    RF interference No alarm 10 V/m
    Operating temperature -30 – +60°C (-22 – +140°F) -20 – +45°C (-4 – +113°F)
    Environment humidity 95% max.
    IP rating IP55
    Mounting Wall, Pole (Outdoor, Indoor)
    Mounting height 0.8 – 1.2 m (2.64 ft – 3.94 ft)
    Weight 500 g (17.7 oz.) 600 g (17.7 oz.)
    Accessories Screw (4×20 mm) ×2 , Wiring sponge ×3 , Masking seal ×3
    Model VXI-R VXI-RAM VXI-RDAM
    Detection method Passive infrared Passive infrared & Microwave
    Coverage 12.0 m (40 ft) wide / 16 zones
    PIR distance limit 12 - 2.5 m (5 levels)
    Detectable speed 0.3 – 1.5 m/s (1 - 5 ft/s)
    Sensitivity 2.0°C (3.6°F) at 0.6 m/s (2 ft/s)
    Power input 3 – 9 VDC (Lithium or Alkaline Battery)
    Current draw 9 μA (standby) / 4 mA (max) at 3 VDC 10 μA (standby) / 4 mA (max) at 3 VDC 18 μA (standby) / 8 mA (max) at 3 VDC
    Alarm period 2.0 ±1 sec.
    Warm-up period Approx. 60 sec. (LED blinks)
    Alarm output N.C. / N.O. Selectable-Solid State Switch 10 VDC 0.01 A (max)
    Trouble output N.C. / N.O. Selectable-Solid State Switch 10 VDC 0.01 A (max)
    LED indicator Disable: During normal operation.
    Enable: During WALK TEST or LED SW on.
    Red: Warm-up, alarm, masking detection.
    Yellow: Warm-up, MW detect.
    RF interference No alarm 10 V/m
    Operating temperature -20 – +60°C (-4 – +140°F) -20 – +45°C (-4 – +113°F)
    Environment humidity 95% max.
    IP rating IP55
    Mounting Wall, Pole (Outdoor, Indoor)
    Mounting height 0.8 – 1.2 m (2.64 ft – 3.94 ft)
    Weight 500 g (17.7 oz.) 600 g (17.7 oz.)
    Accessories Connector for POWER and ALARM, Connector for TROUBLE, Screw (4×20 mm) ×2, Masking seal ×3
bottom of page